Series 700
HydroFlon
Generic Type
Advanced Thermoset Solution Fluoropolymer
Common Usage
An exterior finish coat especially designed for tanks and other exposed steel substrates. HydroFlon has outstanding resistance to ultra-violet light degradation providing unprecedented long-term gloss and color retention with excellent resistance to abrasion and chalking. It is aesthetically pleasing and recommended for coastal environments and on structures where extremely long-term maintenance cycles are desired. NOT FOR IMMERSION SERVICE.
Special Qualifications
Series 700 exceeds the weathering requirements of AWWA Outside Coating System No. 4 (OCS-4) and meets the weathering requirements of AAMA 2604 and 2605.
View more product detailsProduct Data Sheets
- English_Series_700_Hydroflon_pds.pdf
- French_Series_700_Hydroflon_pds.pdf
- Spanish_Series_700_Hydroflon_pds.pdf
Safety Data Sheets
Email this productContact your sales reps for quotes, problem solving advice, extensive technical knowledge, pricing, ordering and field support.
Colors
-
This product is available in 502 colors.
View Available Colors
View available colors in our Color Tool; you can also select and request color swatches.
Finish
Gloss
Volume Solids
60.0 ± 2.0% (mixed) †
Recommended DFT
2.0 to 3.0 mils (50 to 75 microns) per coat. Note: Number of coats and thickness requirements will vary with substrate, application method and exposure. Contact your Tnemec representative.
Volatile Organic Compounds
Unthinned: 2.93 lbs/gallon (351 grams/litre)
Thinned 5% (No. 63 Thinner): 3.10 lbs/gallon (371 grams/litre)
Curing Time
Temperature | To Touch | To Handle | Minimum Recoat ‡ |
---|---|---|---|
90°F (32°C) | 30 minutes | 4-6 hours | 6-8 hours |
70°F (21°C) | 30 minutes | 6-8 hours | 10-12 hours |
50°F (10°C) | 1 hour | 12-15 hours | 16-24 hours |
‡ Maximum recoat: 30 days. Curing time varies with surface temperature, air movement, humidity and film thickness. Note: For faster curing and low-temperature applications, add No. 44-710 Urethane Accelerator; see separate product data sheet.
Intermediate
Series 73, 750, 1075, 1075U, 1095.
Note: When topcoating with Series 700, the following maximum recoat times apply: Over 20, FC20, 27, 66, L69, L69F, N69, N69F, V69, V69F, 135, L140, L140F, N140, N140F, V140, V140F, 161, 14 days; over itself 30 days; over 750, 1075, 1075U, 1095, 45 days; over 1, 60 days; over 27WB, 73, 90-97, H90-97, 91 H2O, 94-H2O, 1224, 90 days.
HAPS
Unthinned: 4.1 lbs/gal solids
Thinned 5% (No. 63 Thinner): 4.1 lbs/gal solids
Theoretical Coverage
962 mil sq ft/gal (23.6 m²/L at 25 microns). †
Number of Components
Two: Part A and Part B
Still have questions? Request the information you’re looking for:
Request InfoHow to Purchase
Tnemec coatings are sold through a select network of local independent sales representatives who can help you find the best product for your needs. Find a rep