Series 245

Ultra-Tread S

Generic Type

Polyurethane Modified Concrete

Common Usage

Ultra-Tread S is a low odor, slurry applied, flowable mortar floor topping designed for monolithic applications in abusive service areas. It provides superior performance to other flooring systems such as acid brick, quarry tile and most polymer flooring systems. Designed for use in food and beverage facilities, pharmaceutical and processing areas, commercial and restaurant kitchens or anywhere a durable floor topping is required. Provides excellent chemical resistance and withstands thermal shock due to hot liquids and aggressive cleaning procedures. Areas may be quickly returned to service within hours of installation, depending on temperature and humidity. Ultra-Tread S is a self-priming base coat that can be applied to 10 day old concrete. It can withstand moisture vapor transmission up to 20 lbs (per ASTM F 1869) and relative humidity up to 99% (per ASTM F 2170).

Special Qualifications

Formulated with antimicrobial properties. Does not support bacteria or fungal growth. Contact your Tnemec representative for specific test results.

Series 245 meets the requirements of LEED-Low-Emitting Materials, Collaborative for High-Performance Schools-Paints & Coatings, WELL Building Standard-VOC Restrictions, and Living Building Challenge–Healthy Interior Performance. Contact your Tnemec representative for more information.

View more product details

Colors

  • 00GR Gray
  • 00RD Red

View Available Colors

View available colors in our Color Tool; you can also select and request color swatches.

Recommended DFT

3/16" to 1/4" (5 mm to 6 mm). Series 245 can be applied as a stand alone mortar (neat) at 3/16"-1/4" (5 mm - 6 mm). Broadcasting with aggregate to refusal at 3/16" (5 mm) neat will yield a total thickness of 1/4" (6 mm), at 1/4" (6 mm) neat will yield a total thickness of 5/16" (8 mm). Important: Series 245 should not exceed 1/2" (13 mm) thickness when applied neat. Refer to coverage rates table for more information. Note: Exceeding the recommended coating thickness may result in blistering of the product. Avoid excessive coating thickness by thoroughly filling voids, depressions and cracks with recommended filler or surfacer prior to Series 245 application.

Theoretical Coverage

23 sq ft per small kit at 1/4" 31 sq ft per small kit at 3/16"

Topcoats

Series N222, 230ESD, 233, 237, 238, 239, 246, 247, 248, 249ESD, 252SC, 256, 257, 280, 280FC, 281, 282, N284, N285, 286, V290, 296, 297. Note: These topcoats may only be used when recommended aggregate has been broadcast to refusal into the wet Series 245 or the cured surface of the Series 245 has been cleaned and thoroughly abraded by grinding prior to topcoating. Note: If Series 247 (tinted), 248 (tinted), V290, or 297 is selected for the finish coat over a broadcast system, a grout coat of Series N222, 233, 237 or 238 (tinted), 256 (tinted), 257 (tinted), 280, 281 or N284 is required. If Series 247 (clear), 248 (clear), N285, or 296 is selected for the finish coat over a broadcast system, a grout coat of 237 or 238 (clear), 256 (clear), 257 (clear), or N284 is required.

Volume Solids

100% (mixed)

Curing Time

Temperature Min. Recoat Light Traffic Place In Service †
75°F (24°C) 6 hours 8 hours 12 hours

† For full resistance to chemicals and steam cleaning, 24 hour cure is needed.
Curing time varies with surface temperature, air movement, humidity and film thickness. Note: For faster curing and low temperature applications, add No. 44-714 Ultra-Tread Accelerator, see separate product data sheet for cure information.

Finish

Matte

Primers

Self-priming

Number of Components

Three—Liquids: Part A & Part B, Aggregate: Part C

Intermediate

Series N222, 233, 237, 238, 239, 252SC, 256, 257. Note: Series 245 must be broadcast to refusal with aggregate, colored quartz or decorative flake if topcoating. Broadcast aggregate or colored quartz at an approximate rate of 0.5 lb per sq ft or 4 to 5 sq ft per pound and decorative flake at an approximate rate of 0.25 lb per sq ft. The Series 245 base coat will account for approximately 1/8"-3/16" of the desired system thickness.

Volatile Organic Compounds

Parts A & B: 0.16 lbs/gallon (19 grams/litre)
Parts A, B & C: 0.07 lbs/gallon (8 grams/litre)

Surfacer/Filler/Patcher

Series 242 (extended with aggregate) or Series 243, 244. Patching should be allowed to cure a minimum of six hours prior to placement of the Series 245 to avoid blistering or doming of the Series 245. Series 215, or 201 or 208 mixed with fumed silica, may be used for small patches or crack repairs. Certain high-early strength, cementitious repair mortars are also acceptable. Contact Tnemec for further qualifications.

Still have questions? Request the information you’re looking for:

Request Info

How to Purchase

Tnemec coatings are sold through a select network of local independent sales representatives who can help you find the best product for your needs. Find a rep

Continue Exploring in the color tool

Close

Color Swatch packet

When you finish selecting, request your Swatch Packet below. Expect your swatch cards in 5-7 business days. Contact your expert Sales Rep at any time.

Sorry, there is a maximum of 6 color swatches.

Request swatch packet

Continue Exploring in the color tool

Close