Series 1071V
Fluoronar
Generic Type
Advanced Thermoset Solution Fluoropolymer
Common Usage
A low VOC, fluoropolymer coating that provides an ultra-durable finish with user friendly brush, roll and conventional spray application. It has outstanding color and gloss retention even in the most severe exposures. Under certain conditions, it may be used to restore aged fluoropolymer coil applied coatings or for OEM applications. Contact Tnemec Technical Services or your local Tnemec representative for details.
Special Qualifications
Series 1071V meets the requirements of LEED-Low-Emitting Materials, Collaborative for High Performance Schools-Paints & Coatings, WELL Building Standard-VOC Restrictions, and Living Building Challenge–Healthy Interior Performance. Contact your Tnemec representative for more information.
View more product detailsProduct Data Sheets
- English_Series_1071V_Fluoronar_pds.pdf
- French_Series_1071V_Fluoronar_pds.pdf
- Spanish_Series_1071V_Fluoronar_pds.pdf
Safety Data Sheets
Email this productContact your sales reps for quotes, problem solving advice, extensive technical knowledge, pricing, ordering and field support.
Colors
-
This product is available in 502 colors.
View Available Colors
View available colors in our Color Tool; you can also select and request color swatches.
Intermediate
Series 73, 750, 1075, 1075U, 1095 (Intermediate coat may be required for some applications, please contact your Tnemec coating consultant.)
Note: When topcoating with Series 1071V, the following maximum recoat times apply: Over 27, 66, L69, L69F, N69, N69F, V69, V69F, 135, 161, 14 days; over itself and 90-75, 30 days; over 750, 1075, 1075U, 1095, 45 days; over 1, 394, 60 days; over 27WB, 73, 90-97, H90-97, 91-H₂O, 94-H₂O, 1224, 90 days.
Curing Time
Temperature | To Touch | To Handle | Minimum Recoat ‡ |
---|---|---|---|
90°F (32°C) | 30 minutes | 4-6 hours | 6-8 hours |
70°F (21°C) | 30 minutes | 6-8 hours | 10-12 hours |
50°F (10°C) | 1 hour | 12-15 hours | 16-24 hours |
‡ Maximum recoat: 30 days. Curing time varies with surface temperature, air movement, humidity and film thickness.
Note: For faster curing and low-temperature applications, add No. 44-710 Urethane Accelerator; see separate product data sheet.
Number of Components
Two: Part A and Part B
Finish
Semi-Gloss
Volume Solids
61.0 ± 2.0% (mixed) †
Theoretical Coverage
978 mil sq ft/gal (24.0 m²/L at 25 microns) †
HAPS
Unthinned: 0.29 lbs/gal solids
Thinned 10% (No. 65 Thinner): 0.29 lbs/gal solids
Thinned 10% (No. 63 Thinner): 0.35 lbs/gal solids †
Primers
Series 1, 27, 27WB, 66, L69, L69F, N69, N69F, V69, V69F, 90-75, 90-97, H90-97, 91-H₂O, 94-H₂O, 115, 118, 135, 161, 394, 1224. Note: Series 1 and 394 require an intermediate coat prior to topcoating with Series 1071V. Note: Series 118 is typically used to overcoat, sound, existing coating systems. See product data sheet for more information.
Volatile Organic Compounds
Unthinned: 1.11 lbs/gallon (133 grams/litre)
Unthinned: 0.55 lbs/gallon (66 grams/litre) (TBAc Exempt)
Thinned 10% (No. 65 Thinner): 1.87 lbs/gallon (224 grams/litre)
Thinned 10% (No. 65 Thinner): 0.55 lbs/gallon (66 grams/litre) (TBAc Exempt)
Thinned 10% (No. 63 Thinner): 1.77 lbs/gallon (213 grams/litre)
Thinned 10% (No. 63 Thinner): 1.35 lbs/gallon (161 grams/litre) (TBAc Exempt) †
Recommended DFT
2.0 to 3.0 mils (50 to 75 microns) per coat. Note: Number of coats and thickness requirements will vary with substrate, application method and exposure. Contact your Tnemec representative.
Still have questions? Request the information you’re looking for:
Request InfoHow to Purchase
Tnemec coatings are sold through a select network of local independent sales representatives who can help you find the best product for your needs. Find a rep