Series FC22 | Epoxoline

Generic Type Modified Polyamine Epoxy
Common Usage An advanced generation, 100% solids epoxy liner for the protection of steel and concrete. It provides excellent resistance to abrasion and is suitable for immersion and chemical contact. For use on the interior and exterior of steel or concrete tanks, reservoirs, and pipes in potable water service.
Colors WH08 White. Note: Epoxies chalk with extended exposure to sunlight. Lack of ventilation, incomplete mixing, miscatalyzation or the use of heaters that emit carbon dioxide and carbon monoxide during application and initial stages of curing may cause yellowing to occur.
Finish Semi-Gloss
Surfacer/Filler/Patcher Series 215, 218
Primers Self-priming or Series 1, 91-H2O, 94-H2O, L140, L140F, N140, N140F, V140, V140F
Volume Solids 100% (mixed)
Recommended DFT 16.0 to 40.0 mils (405 to 1015 microns) in a one coat application. Note: Thickness requirements will vary with substrate, application method and exposure. Contact your Tnemec representative.
Curing Time
TemperatureTo HandleMax to RecoatImmersion
110°F (43°C)1 hour7 days16 hours
75°F (24°C)6 hours7 days24 hours
35°F (2°C)12 hours7 days48 hours
Note: These times are based on a 20.0 mil (500 micron) dry film thickness. Curing time varies with surface temperature, air movement, humidity and film thickness. Ventilation: When used as a tank lining or in enclosed areas, provide adequate ventilation during application and cure.
Volatile Organic Compounds EPA Method 24 Unthinned: 0.04 lbs/gallon (5 grams/litre)
Theoretical Coverage 1,604 mil sq ft/gal (39.4 m²/L at 25 microns.) See APPLICATION for coverage rates.
Number of Components Two: 1 (Part A amine) to 2 (Part B epoxy)