Series 66 | Hi-Build Epoxoline

Generic Type Polyamide Epoxy
Common Usage Industry standard for epoxy coatings for over 30 years. Known for its forgiving application characteristics in adverse and varied conditions, and for benchmark performance.
Colors Refer to Tnemec Color Guide. Note: Epoxies chalk with extended exposure to sunlight and may yellow on aging. Lack of ventilation, incomplete mixing, miscatalyzation or the use of heaters that emit carbon dioxide and carbon monoxide during application and initial stages of curing may accelerate any potential yellowing.
Finish Satin
Primers Steel: Self-priming or Series 1, 20, FC20, 37H, N69, 90, 91-H2O, 94-H2O, 161, 394, 530
Galvanized Steel and Non-Ferrous Metal: Self-priming
Concrete: Self-priming, 54-660, 201, 216, 218
CMU: 54-562, 54-660, 130, 216, 218
Drywall: 51-792 for dry interior environments
Note: A maximum recoat time may apply depending on the topcoat specified. Refer to the applicable topcoat product sheet for information on product specific maximum recoat times.
Topcoats 46H-413, 66, N69, 73, 84, 104, 113, 114, 161, 262, 265, 290, 291, 1070, 1071, 1072, 1074, 1074U, 1075, 1075U, 1077, 1078. Refer to COLORS on applicable topcoat data sheets for additional information. Note: A maximum recoat time may apply depending on the topcoat specified. Refer to the applicable topcoat product sheet for information on product specific maximum recoat times.
Volume Solids 56.0 ± 2.0% (mixed) †
Recommended DFT 2.0 to 6.0 mils (50 to 150 microns) per coat.
Note: Number of coats and thickness requirements will vary with substrate, application method and exposure. Contact your Tnemec representative.
Curing Time
Temperature To Touch To Handle To Recoat Immersion
75°F (24°C) 2 hours 10 hours 12 hours 7 days

Curing time varies with surface temperature, air movement, humidity and film thickness.
Ventilation: When used as a tank lining or in enclosed areas, provide adequate ventilation during application and cure. Reference guidelines contained in the latest edition of AWWA D 102.
Volatile Organic Compounds Unthinned: 3.02 lbs/gallon (362 grams/litre)
Thinned 5%: 3.20 lbs/gallon (384 grams/litre)
Thinned 10%: 3.37 lbs/gallon (404 grams/litre) †
Theoretical Coverage 898 mil sq ft/gal (22.0 m²/L at 25 microns). See APPLICATION for coverage rates. †
Number of Components Two: Part A and Part B