Series 431 | Perma-Shield PL

Generic Type Modified Polyamine Ceramic Epoxy
Common Usage A 100% solids, abrasion-resistant lining specifically designed for wastewater immersion and fume environments and exposure to corrosive soils. Provides low permeation to H2S gas, protects against MIC and provides chemical resistance to steel, ductile iron pipe and fittings for severe wastewater or buried exposures. A coal-tar free, resin-rich formulation with low pigment volume concentration (PVC) for maximum performance.
Colors 5024 Sewer Pipe Green. Note: Epoxies chalk with extended exposure to sunlight.
Finish Gloss
Primers Self-priming, Series N69 or Series N140. Note: Series 431 must be applied to Series N69 or N140 within 7 days. Scarify the surface with fine abrasive before topcoating if exceeding this maximum recoat window.
Volume Solids 100% (mixed)
Recommended DFT Carbon Steel: 30.0 to 50.0 mils (762 to 1270 microns) in one or more coats.
Ductile Iron: 40 mils (1015 microns) (nominal) in one or more coats.
Note: Number of coats and thickness requirements will vary with substrate, application method and exposure. Contact your Tnemec representative.
Curing Time
TemperatureSet to TouchMax. RecoatTo Place in Service
90°F (32°C)1-2 hours7 days24 hours
75°F (24°C)2-3 hours7 days2 days
55°F (13°C)8-9 hours7 days3 days
Note: If more than 7 days have elapsed between coats, the Series 431 coated surface must be mechanically abraded (scarified) before topcoating. Curing time will vary with surface temperature, air movement, humidity and film thickness.
Volatile Organic Compounds EPA Method 24: 0.19 lbs/gallon (23 grams/litre)
HAPS 0.00 lbs/gal solids
Theoretical Coverage 1,604 mil sq ft/gal (39.4 m²/L at 25 microns). See APPLICATION section for coverage rates.
Number of Components Two: Part A (amine) and Part B (epoxy)
1
Category
2
Chemical Name(required)
3
Concentration
4
What is this?

Note: Not Recommended (NR), Not Tested (NT), Please Call (PC)

 

Chemical Recommended Use - What is this?

The chemical resistance data listed on this website should only be used for general reference purposes. Substrates, temperatures, chemical combinations, and other variables can affect the performance of a coating in chemical exposure. Please contact your local to finalize the most appropriate system for your project.

Click the following button to download a PDF of the list of chemicals below.

*Results are NOT suitable for direct or indirect food contact. Intended use exposure results relate to product's performance and substrate protection capabilities only.


Recommended Use
Chemical Occasional Contact Frequent Contact Secondary Containment Cargo Immersion Immersion Service
*Results are NOT suitable for direct or indirect food contact. Intended use exposure results relate to product's performance and substrate protection capabilities only.
  • Color cards, swatches and fan decks are offered at no charge, by request , for more accurate color selection. Expert custom color matching is also available by contacting your Tnemec Coatings Consultant .
  • Deeptone colors may be more expensive than lighter colors. Please contact your Tnemec Coatings Consultant to verify product/color availability and pricing.

Products Available In Sewer Pipe Green 5024

Sewer Pipe Green| 5024 rgb 68,144,119
Swatch Unavailable
These digital colors should not be used to finalize your color selection. Please read our disclaimer . Use the color swatch tool on the left to request official color swatches.

Color Swatch Packet

Request another

(maximum 6 color swatches)

You haven't added any color swatches to your packet. Select some colors now by clicking a color above and then clicking the 'Request a Swatch' button on the color.

The products listed below are not exact equivalents. They are only products that you may consider as alternatives in a general sense. Substrate type, condition, temperatures, surface preparation, primer/topcoat selection and intended use are just a few factors that will affect product selection. Please contact your local Tnemec Coatings Consultant for product recommendations.

This ProductModified Polyamine Ceramic Epoxy
Volume Solids Rec. DFT V.O.C. # of Components
100% (mixed) Carbon Steel: 30.0 to 50.0 mils (762 to 1270 microns) in one or more coats.
Ductile Iron: 40 mils (1015 microns) (nominal) in one or more coats.
Note: Number of coats and thickness requirements will vary with substrate, application method and exposure. Contact your Tnemec representative.
EPA Method 24: 0.19 lbs/gallon (23 grams/litre) Two: Part A (amine) and Part B (epoxy)
Series 435 | Perma-Glaze Modified Polyamine Epoxy
Hide this product's data
Volume Solids Rec. DFT V.O.C. # of Components
100% (mixed) Steel: 15.0 to 40.0 mils (380 to 1015 microns) in one or two coats.
Concrete: 30.0 to 40.0 mils (760 to 1015 microns) in one or two coats.
Hi-Build Option: 40.0 to 80.0 mils (1015 to 2030 microns) in one or two coats.
Glaze Coat Option (over Series 434 or 436): 15.0 to 20.0 mils (380 to 510 microns).
Note: Number of coats and thickness requirements will vary with substrate, application method and exposure. Contact your Tnemec representative.
EPA Method 24: 0.23 lbs/gallon (27 grams/litre) Two: Part A (Amine) and Part B (Epoxy)