find your coatings consultants
Find and contact a coatings consultant near you.

Series 27 | F.C. Typoxy

Generic Type Polyamide Epoxy
Common Usage Versatile low-temperature coating ideally suited for steel fabrication and OEM applications. Also widely used as a field tie-coat. Provides fast curing and rapid handling capabilities. Note: Series 27 conforms with air pollution regulations limiting Volatile Organic Compounds (VOC) to a maximum of 340 grams/litre (2.8 lbs/gal).
Colors Refer to Tnemec Color Guide. Note: Epoxies chalk with extended exposure to sunlight. Lack of ventilation, incomplete mixing, miscatalyzation or the use of heaters that emit carbon dioxide and carbon monoxide during application and initial stages of curing may cause yellowing to occur.
Finish Flat
Primers Steel: Self-priming or Series 1, 37H, 66, L69, L69F, N69, N69F, V69, V69F, 90, 94-H2O, 135, 394, 530
Galvanized Steel and Non-Ferrous Metal: Self-priming, Series 66 or L69, L69F, N69, N69F, V69, V69F.
Topcoats Series 2H, 30, 66, 73, 113, 114, 115, 175, 700, V700, 701, V701, 1028, 1029, 1070, 1070V, 1071, 1071V, 1072, 1072V, 1074, 1075, 1077, 1078, 1078V. Note: Series 27 exterior exposed for 3 weeks or longer requires an epoxy intermediate coat or scarification prior to topcoating with Series 2H. When topcoating with Series 700, V700, 701, V701, 1070, 1070V, 1071, 1071V, 1072, 1072V, 1078, or 1078V over Series 27, a 14 day maximum recoat time applies. Refer to appropriate topcoat data sheet for additional information.
Volume Solids 58.0 ± 2.0% (mixed) †
Recommended DFT 2.0 to 6.0 mils (50 to 150 microns) per coat. Note: Number of coats and thickness requirements will vary with substrate, application method and exposure. Contact your Tnemec representative.
Curing Time
Temperature To Touch To Handle To Recoat
75°F (24°C) 1/2 hour 2 hours 3 hours
65°F (18°C) 3/4 hour 4 hours 5-6 hours
55°F (11°C) 1 hour 4-5 hours 6-8 hours
45°F (7°C) 1-2 hours 6-8 hours 9-12 hours
35°F (2°C) 2-3 hours 9-12 hours 12-15 hours
Curing time varies with surface temperature, air movement, humidity and film thickness.
Volatile Organic Compounds Unthinned: 2.36 lbs/gallon (282 grams/litre)
Thinned 10% (No. 60 Thinner): 2.83 lbs/gallon (339 grams/litre)
Thinned 10% (No. 4 Thinner): 2.83 lbs/gallon (339 grams/litre) †
HAPS Unthinned: 2.59 lbs/gal solids
Thinned 10% (No. 60 Thinner): 2.59 lbs/gal solids
Thinned 10% (No. 4 Thinner): 3.54 lbs/gal solids
Theoretical Coverage 930 mil sq ft/gal (22.8 m²/L at 25 microns). See APPLICATION for coverage rates. †
Number of Components Two: Part A and Part B
1
Category
2
Chemical Name(required)
3
Concentration
4
What is this?

Note: Not Recommended (NR), Not Tested (NT), Please Call (PC)

 

Chemical Recommended Use - What is this?

The chemical resistance data listed on this website should only be used for general reference purposes. Substrates, temperatures, chemical combinations, and other variables can affect the performance of a coating in chemical exposure. Please contact your local to finalize the most appropriate system for your project.

Click the following button to download a PDF of the list of chemicals below.

*Results are NOT suitable for direct or indirect food contact. Intended use exposure results relate to product's performance and substrate protection capabilities only.


Recommended Use
Chemical Occasional Contact Frequent Contact Secondary Containment Cargo Immersion Immersion Service
*Results are NOT suitable for direct or indirect food contact. Intended use exposure results relate to product's performance and substrate protection capabilities only.
  • Color cards, swatches and fan decks are offered at no charge, by request , for more accurate color selection. Expert custom color matching is also available by contacting your Tnemec Coatings Consultant .
  • Deeptone colors may be more expensive than lighter colors. Please contact your Tnemec Coatings Consultant to verify product/color availability and pricing.

Products Available In Lightpole 24GR

Lightpole| 24GR rgb 196,196,187
Request a Swatch Swatch Unavailable
These digital colors should not be used to finalize your color selection. Please read our disclaimer . Use the color swatch tool on the left to request official color swatches.

Color Swatch Packet

Request another

(maximum 6 color swatches)

You haven't added any color swatches to your packet. Select some colors now by clicking a color above and then clicking the 'Request a Swatch' button on the color.

The products listed below are not exact equivalents. They are only products that you may consider as alternatives in a general sense. Substrate type, condition, temperatures, surface preparation, primer/topcoat selection and intended use are just a few factors that will affect product selection. Please contact your local Tnemec Coatings Consultant for product recommendations.

This ProductPolyamide Epoxy
Volume Solids Rec. DFT V.O.C. # of Components
58.0 ± 2.0% (mixed) † 2.0 to 6.0 mils (50 to 150 microns) per coat. Note: Number of coats and thickness requirements will vary with substrate, application method and exposure. Contact your Tnemec representative. Unthinned: 2.36 lbs/gallon (282 grams/litre)
Thinned 10% (No. 60 Thinner): 2.83 lbs/gallon (339 grams/litre)
Thinned 10% (No. 4 Thinner): 2.83 lbs/gallon (339 grams/litre) †
Two: Part A and Part B
Series 135 | Chembuild Modified Polyamidoamine Epoxy
Hide this product's data
Volume Solids Rec. DFT V.O.C. # of Components
84.0 ± 2.0% (mixed) † Conventional Build: 4.0 to 6.0 mils (100 to 150 microns) per coat.
Hi-Build: 7.0 to 9.0 mils (180 to 230 microns) per coat.
Note: Number of coats and thickness requirements will vary with substrate, application method and exposure. Contact your Tnemec representative.
EPA Method 24 Unthinned: 0.72 lbs/gallon (86 grams/litre)
Thinned 15% (No. 19 Thinner): 1.91 lbs/gallon (229 grams/litre)
Thinned 15% (No. 18 Thinner): 2.05 lbs/gallon (246 grams/litre)
Thinned 15% (No. 62 Thinner): 0.72 lbs/gallon (86 grams/litre) †
Two: Part A and Part B