Generic Type Polyurethane Modified Concrete
Common Usage Ultra-Tread MVT is a high performance moisture control system designed to reduce moisture vapor emissions prior to the application of non-breathing, polymer floor topping finishes. Ultra-Tread MVT is a low odor, self-priming, base coat that can be applied to 10 day old concrete. It can withstand moisture vapor transmission up to 20 lbs (per ASTM F 1869) and relative humidity up to 99% (per ASTM F 2170). This unique, self-leveling slurry system is typically applied by V-notch trowel or squeegee, backrolled with a loop roller and broadcast to refusal with 30/50 mesh aggregate, colored quartz or decorative flake yielding an approximate 1/8" thick base layer.
Colors Neutral/Tan as supplied. Note: Series 244 Part D field colorants are available in 00GR Gray and 00RD Red. Black, blue, beige and green are also available with additional lead time. Series 244 Part D field colorants are ordered separately. When tinting Series 241, add one colorant pack per kit.
Surfacer/Filler/Patcher Series 241 (extended with aggregate) or Series 243. Patching should be allowed to cure a minimum of six hours prior to placement of the Series 241 to avoid blistering or doming of the Series 241. Series 215, or 201 or 208 mixed with fumed silica, may be used for small patches or crack repairs. Certain high-early strength, cementious repair mortars are also acceptable. Contact Tnemec for further qualifications.
Primers Self-priming
Intermediate Series 222, 223, 224, 233, 237, 238, 239, 252SC, 256. Note: Series 241 must be broadcast to refusal with aggregate, colored quartz or decorative flake if topcoating. Broadcast aggregate or colored quartz at an approximate rate of 0.8 lb per sq ft and decorative flake at an approximate rate of 0.25 lb per sq ft or 4 to 5 sq ft per pound. The Series 241 base coat will account for approximately 1/8"-3/16" of the desired system thickness.
Topcoats Series 233, 237, 238, 239, 246, 247, 248, 252SC, 256, 280, 281, 282, 284, 285, 286, 290, 291, 294, 295, 296, 297. Note: These topcoats may only be used when recommended aggregate has been broadcast to refusal into the wet Series 241. Note: If Series 247 (tinted), 248 (tinted), 290, 291 or 297 is selected for the finish coat over a broadcast system, a grout coat of Series 237 or 238 (tinted), 256 (tinted), 280 or 281 is required. If Series 247 (clear), 248 (clear), 285, 294, 295 or 296 is selected for the finish coat over a broadcast system, a grout coat of 237 or 238 (clear), 256 (clear) or 284 is required.
Volume Solids 100% (mixed)
Recommended DFT 46.0 to 52.0 mils (1168 to 1320 microns) applied neat. Film thickness, after broadcasting with aggregate, is approximately 1/8". Refer to coverage rates table for more information. Note: Exceeding the recommended coating thickness may result in blistering of the product. Avoid excessive coating thickness by thoroughly filling voids, depressions and cracks with recommended filler or surfacer prior to Series 241 application.
Curing Time
TemperatureMin. RecoatLight TrafficPlace in Service
75°F (24°C)6 hours8 hours12 hours
For full resistance to chemicals and heavy traffic, 24 hour cure is needed. Curing time varies with surface temperature, air movement, humidity and film thickness. Note: For faster curing and low temperature applications, add No. 44-714 Ultra-Tread Accelerator, see separate product data sheet for cure information.
Volatile Organic Compounds Parts A & B: 0.05 lbs/gallon (5.6 grams/litre)
Parts A, B & C: 0.03 lbs/gallon (3.9 grams/litre)
Theoretical Coverage 70-80 sq ft (6.50-7.43 m²) per small kit
Number of Components Liquids - Two: Part A & Part B
Aggregate - One: Part C
Field Colorant - One: (Optional) If tinting Series 241, order Series 244 Part D color packs, available in 00GR Gray and 00RD Red. Must be ordered separately.
1
Category
2
Chemical Name(required)
3
Concentration
4
What is this?

Note: Not Recommended (NR), Not Tested (NT), Please Call (PC)

 

Chemical Recommended Use - What is this?

The chemical resistance data listed on this website should only be used for general reference purposes. Substrates, temperatures, chemical combinations, and other variables can affect the performance of a coating in chemical exposure. Please contact your local to finalize the most appropriate system for your project.

Click the following button to download a PDF of the list of chemicals below.

1 Product is NOT suitable for direct or indirect food contact. Intended Use and temperature information relates    to product's performance capabilities only.

2 Product is suitable for direct or indirect food contact. Reference the product data sheet for more information.


Recommended Use
Chemical Occasional Contact Frequent Contact Secondary Containment Cargo Immersion Immersion Service

1 Product is NOT suitable for direct or indirect food contact. Intended Use and temperature information relates    to product's performance capabilities only.

2 Product is suitable for direct or indirect food contact. Reference the product data sheet for more information.

  • Color cards, swatches and fan decks are offered at no charge, by request , for more accurate color selection. Expert custom color matching is also available by contacting your Tnemec Coatings Consultant .
  • Deeptone colors may be more expensive than lighter colors. Please contact your Tnemec Coatings Consultant to verify product/color availability and pricing.
These digital colors should not be used to finalize your color selection. Please read our disclaimer . Use the color swatch tool on the left to request official color swatches.

Color Swatch Packet

Request another

(maximum 6 color swatches)

You haven't added any color swatches to your packet. Select some colors now by clicking a color above and then clicking the 'Request a Swatch' button on the color.

The products listed below are not exact equivalents. They are only products that you may consider as alternatives in a general sense. Substrate type, condition, temperatures, surface preparation, primer/topcoat selection and intended use are just a few factors that will affect product selection. Please contact your local Tnemec Coatings Consultant for product recommendations.

This ProductPolyurethane Modified Concrete
Volume Solids Rec. DFT V.O.C. # of Components
100% (mixed) 46.0 to 52.0 mils (1168 to 1320 microns) applied neat. Film thickness, after broadcasting with aggregate, is approximately 1/8". Refer to coverage rates table for more information. Note: Exceeding the recommended coating thickness may result in blistering of the product. Avoid excessive coating thickness by thoroughly filling voids, depressions and cracks with recommended filler or surfacer prior to Series 241 application. Parts A & B: 0.05 lbs/gallon (5.6 grams/litre)
Parts A, B & C: 0.03 lbs/gallon (3.9 grams/litre)
Liquids - Two: Part A & Part B
Aggregate - One: Part C
Field Colorant - One: (Optional) If tinting Series 241, order Series 244 Part D color packs, available in 00GR Gray and 00RD Red. Must be ordered separately.
Series 245 | Ultra-Tread S Polyurethane Modified Concrete
Hide this product's data
Volume Solids Rec. DFT V.O.C. # of Components
100% (mixed) 3/16" to 1/4" (5 mm to 6 mm). Series 245 can be applied as a stand alone mortar (neat) at 3/16"-1/4" (5 mm - 6 mm). Broadcasting with aggregate to refusal at 3/16" (5 mm) neat will yield a total thickness of 1/4" (6 mm), at 1/4" (6 mm) neat will yield a total thickness of 5/16" (8 mm). Important: Series 245 should not exceed 1/2" (13 mm) thickness when applied neat. Refer to coverage rates table for more information. Note: Exceeding the recommended coating thickness may result in blistering of the product. Avoid excessive coating thickness by thoroughly filling voids, depressions and cracks with recommended filler or surfacer prior to Series 245 application. Parts A & B: 0.16 lbs/gallon (19 grams/litre)
Parts A, B & C: 0.07 lbs/gallon (8 grams/litre)
Four—Liquids: Part A & Part B, Aggregate: Part C, Colorant