find your coatings consultants
Find and contact a coatings consultant near you.

Series 1075 | Endura-Shield II

Generic Type Aliphatic Acrylic Polyurethane
Common Usage A coating highly resistant to abrasion, wet conditions, corrosive fumes and exterior weathering. High build quality combines with project specific primers for two-coat, labor saving systems. Fast curing options are available; see Curing Time below. Product has some applications as a direct to metal finish. Contact your Tnemec representative for more details. NOT FOR IMMERSION SERVICE.
Colors Refer to Tnemec Color Guide. Note: Certain colors may require multiple coats depending on method of application and finish coat color. When feasible, the preceding coat should be in the same color family, but noticeably different.
Finish Semi-gloss
Primers Steel: Series 1, 20, FC20, 27, 66, L69, L69F, N69, N69F, V69, V69F, 90-97, 91-H2O, 94-H2O, 104, 135, L140, L140F, N140, N140F, V140, V140F, 141, 161, 394, 530
Galvanized Steel and Non-Ferrous Metal: Series 27, 66, L69, L69F, N69, N69F, 135, 161
Concrete: Series 66, L69, L69F, N69, N69F, 84, 104, 161
CMU: 54-660, 130. Intermediate coat required.
Note: Before topcoating with Series 1075, Series 530 exterior exposed for more than 24 hours must first be scarified or receive an intermediate coat of Tnemec polyamide epoxy. Recoat windows for other primers may apply. See those data sheets for additional information.
Volume Solids 71 ± 2.0% (mixed) †
Recommended DFT 2.0 to 5.0 mils (50 to 125 microns) per coat. Note: Number of coats and thickness requirements will vary with substrate, application method and exposure. Contact your Tnemec representative.
Curing Time
Temperature To Handle To Recoat Resist Moisture
95°F (35°C) 4 hours 5 hours 3 hours
75°F (24°C) 6 hours 8 hours 5 hours
55°F (13°C) 12 hours 16 hours 9 hours
35°F (2°C) 36 hours 48 hours 20 hours

Curing time varies with surface temperature, air movement, humidity and film thickness. If coating is exposed to moisture before the applicable cure parameters are met, dull, flat or spotty appearing areas may develop. Note: For faster curing and low-temperature applications, add No. 44-710 Urethane Accelerator; see separate product data sheet. Contact Tnemec Technical Services for force curing times and temperatures.
Volatile Organic Compounds EPA Method 24 †
Unthinned Maximum 15%
(No. 39 Thin.)
Max 15%
(No.42 Thin.)
Max 15%
(No. 48 Thin.)
Max 15%
(No. 56 Thin.)
Max 15%
(No. 63 Thin.)
1.84 lbs/gal (220 g/l) 2.42 lbs/gal (290 g/l) 2.48 lbs/gal (297 g/l) 2.55 lbs/gal (305 g/l) 1.94 lbs/gal (232 g/l) 2.54 lbs/gal (305 g/l)
HAPS
Unthinned Maximum 15%
(No. 39 Thin.)
Max 15%
(No. 42 Thin.)
Max 15%
(No. 48 Thin.)
Max 15%
(No. 56 Thin.)
Max 15%
(No. 63 Thin.)
0.0 lbs/gal 0.0 lbs/gal 0.0 lbs/gal 0.0 lbs/gal 0.0 lbs/gal 0.0 lbs/gal
Theoretical Coverage 1,132 mil sq ft/gal (27.8 m²/L at 25 microns). See APPLICATION for coverage rates. †
Number of Components Two: Part A and Part B
1
Category
2
Chemical Name(required)
3
Concentration
4
What is this?

Note: Not Recommended (NR), Not Tested (NT), Please Call (PC)

 

Chemical Recommended Use - What is this?

The chemical resistance data listed on this website should only be used for general reference purposes. Substrates, temperatures, chemical combinations, and other variables can affect the performance of a coating in chemical exposure. Please contact your local to finalize the most appropriate system for your project.

Click the following button to download a PDF of the list of chemicals below.

*Results are NOT suitable for direct or indirect food contact. Intended use exposure results relate to product's performance and substrate protection capabilities only.


Recommended Use
Chemical Occasional Contact Frequent Contact Secondary Containment Cargo Immersion Immersion Service
*Results are NOT suitable for direct or indirect food contact. Intended use exposure results relate to product's performance and substrate protection capabilities only.
  • Color cards, swatches and fan decks are offered at no charge, by request , for more accurate color selection. Expert custom color matching is also available by contacting your Tnemec Coatings Consultant .
  • Deeptone colors may be more expensive than lighter colors. Please contact your Tnemec Coatings Consultant to verify product/color availability and pricing.

Products Available In Vapor Mist 01GR

Vapor Mist| 01GR rgb 211,211,216
Request a Swatch Swatch Unavailable
These digital colors should not be used to finalize your color selection. Please read our disclaimer . Use the color swatch tool on the left to request official color swatches.

Color Swatch Packet

Request another

(maximum 6 color swatches)

You haven't added any color swatches to your packet. Select some colors now by clicking a color above and then clicking the 'Request a Swatch' button on the color.

The products listed below are not exact equivalents. They are only products that you may consider as alternatives in a general sense. Substrate type, condition, temperatures, surface preparation, primer/topcoat selection and intended use are just a few factors that will affect product selection. Please contact your local Tnemec Coatings Consultant for product recommendations.

This ProductAliphatic Acrylic Polyurethane
Volume Solids Rec. DFT V.O.C. # of Components
71 ± 2.0% (mixed) † 2.0 to 5.0 mils (50 to 125 microns) per coat. Note: Number of coats and thickness requirements will vary with substrate, application method and exposure. Contact your Tnemec representative. EPA Method 24 †
Unthinned Maximum 15%
(No. 39 Thin.)
Max 15%
(No.42 Thin.)
Max 15%
(No. 48 Thin.)
Max 15%
(No. 56 Thin.)
Max 15%
(No. 63 Thin.)
1.84 lbs/gal (220 g/l) 2.42 lbs/gal (290 g/l) 2.48 lbs/gal (297 g/l) 2.55 lbs/gal (305 g/l) 1.94 lbs/gal (232 g/l) 2.54 lbs/gal (305 g/l)
Two: Part A and Part B
Series 73 | Endura-Shield Aliphatic Acrylic Polyurethane
Hide this product's data
Volume Solids Rec. DFT V.O.C. # of Components
58.0 ± 2.0% (mixed) † 2.0 to 5.0 mils (50 to 125 microns) per coat. Note: Number of coats and thickness requirements will vary with substrate, application method and exposure. Contact your Tnemec representative.
UnthinnedThinned 10% (Max) (No. 39 Thinner)Thinned 10% (Max) (No. 42 Thinner)Thinned 10% (Max) (No. 48 Thinner)Thinned 10% (Max) (No. 56 Thinner)Thinned 10% (Max) (No. 63 Thinner)
2.70 lbs/gallon (324 grams/litre)3.05 lbs/gallon (366 grams/litre)3.10 lbs/gallon (371 grams/litre)3.15 lbs/gallon (378 grams/litre)2.76 lbs/gallon (331 grams/litre)3.07 lbs/gallon (368 grams/litre)

Two: Part A and Part B
Series 1074 | Endura-Shield II Aliphatic Acrylic Polyurethane
Hide this product's data
Volume Solids Rec. DFT V.O.C. # of Components
66 ± 2.0% (mixed) † 2.0 to 5.0 mils (50 to 125 microns) per coat. Note: Number of coats and thickness requirements will vary with substrate, application method and exposure. Contact your Tnemec representative. EPA Method 24 †
Unthinned Max 10%
(No. 39 Thin.)
Max 9%
(No. 42 Thin.)
Max 8%
(No. 48 Thin)
2.24 lbs/gal
(269 g/l)
2.83 lbs/gal
(339 g/l)
2.83 lbs/gal
(339 g/l)
2.84 lbs/gal
(340 g/l)
Two: Part A and Part B
Series 1081 | Endura-Shield Waterborne Acrylic Polyurethane
Hide this product's data
Volume Solids Rec. DFT V.O.C. # of Components
61.0 ± 2.0% (mixed) † 2.0 to 3.0 mils (50 to 75 microns) per coat. Note: Number of coats and thickness requirements will vary with substrate, application method, and exposure. Caution: Application of coating below minimum or above maximum recommended dry film thicknesses may adversely affect coating aesthetics and performance. Excessive film thicknesses will cause microbubbling. Contact your Tnemec representative. Unthinned: 0.73 lbs/gallon (88 grams/litre)
Thinned 5% (Water): 0.73 lbs/gallon (88 grams/litre)
Thinned 5% (No. 66 Thinner): 1.23 lbs/gallon (147 grams/litre) †
Two: Part A and Part B