find your coatings consultants
Find and contact a coatings consultant near you.

Series 1029 | Enduratone

Generic Type HDP Acrylic Polymer
Common Usage Water-based, low VOC, High Dispersion Pure acrylic polymer coating providing excellent long term protection in both interior/exterior exposures. May be applied by spray, brush or roller over a variety of solvent and waterborne steel primers. May also be used over many aged coatings. It is mildew resistant and exhibits very good gloss and color stability. Application methods include "dry-fall" under certain conditions (See Application). Note: Series 1029's "dry-fall" characteristics help reduce the potential for overspray problems on buildings and surrounding property.
Colors Refer to Tnemec Color Guide. Note: Certain colors may require multiple coats depending on method of application and finish coat color. When feasible, the preceding coat should be in the same color family (blue, gray, etc.), but noticeably different.
Finish Low semi-gloss - Note: Final gloss level of topcoat can vary depending on number of coats applied. One coat will generally result in a lower sheen than two coats of the material.
Primers Wood: Series 10-99W, V10-99W or 151-1051
Steel: Series 1, 10, 22, 30, 37H, 66, L69, L69F, N69, N69F, V69, V69F, 90-97, 90G-1K97, 91-H2O, 94-H2O, 113, 115, 135, L140, L140F, N140, N140F, V140, V140F, 141, 161, 287, 394. Note: Allow Series 10, V10 and 37H to cure three days before topcoating. Additionally, Series 1, 90-97, 90G-1K97, 91-H2O, 94-H2O and 394 must be exterior exposed for three days prior to topcoating. Note: This product exhibits direct-to-metal capabilities for dry interior environments. Contact Tnemec Technical Service for more information.
Aluminum & Galvanized: Series 66, L69, L69F, N69, N69F, V69, V69F, 115, 135
Concrete: Self-priming or Series 6, 54, 66, L69, L69F, N69, N69F, V69, V69F, 130, 151, 156, 180, 287, 1254
CMU: Series 54, 130, 1254
Drywall: Series 51, 151-1051, 287
Topcoats Series 1028, 1080, 1081
Volume Solids 40.0 ± 2.0% †
Recommended DFT 2.0 to 3.0 mils (50 to 75 microns) per coat.
Curing Time
Temperature To Touch To Handle To Recoat To Resist Moisture
75°F (24°C) 30 minutes 2 hours 2 hours 6 hours
Curing time varies with surface temperature, air movement, humidity and film thickness.
Volatile Organic Compounds Unthinned: 0.79 lbs/gallon (94 grams/litre)
Thinned 5%: 0.79 lbs/gallon (94 grams/litre) †
HAPS Unthinned: 0.31 lbs/gal solids
Thinned 5%: 0.31 lbs/gal solids
Theoretical Coverage 643 mil sq ft/gal (15.8 m²/L at 25 microns). See APPLICATION for coverage rates. †
Number of Components One
1
Category
2
Chemical Name(required)
3
Concentration
4
What is this?

Note: Not Recommended (NR), Not Tested (NT), Please Call (PC)

 

Chemical Recommended Use - What is this?

The chemical resistance data listed on this website should only be used for general reference purposes. Substrates, temperatures, chemical combinations, and other variables can affect the performance of a coating in chemical exposure. Please contact your local to finalize the most appropriate system for your project.

Click the following button to download a PDF of the list of chemicals below.

1 Product is NOT suitable for direct or indirect food contact. Intended Use and temperature information relates    to product's performance capabilities only.

2 Product is suitable for direct or indirect food contact. Reference the product data sheet for more information.


Recommended Use
Chemical Occasional Contact Frequent Contact Secondary Containment Cargo Immersion Immersion Service

1 Product is NOT suitable for direct or indirect food contact. Intended Use and temperature information relates    to product's performance capabilities only.

2 Product is suitable for direct or indirect food contact. Reference the product data sheet for more information.

  • Color cards, swatches and fan decks are offered at no charge, by request , for more accurate color selection. Expert custom color matching is also available by contacting your Tnemec Coatings Consultant .
  • Deeptone colors may be more expensive than lighter colors. Please contact your Tnemec Coatings Consultant to verify product/color availability and pricing.

Products Available In Vapor Mist 01GR

Vapor Mist| 01GR rgb 211,211,216
Request a Swatch Swatch Unavailable
These digital colors should not be used to finalize your color selection. Please read our disclaimer . Use the color swatch tool on the left to request official color swatches.

Color Swatch Packet

Request another

(maximum 6 color swatches)

You haven't added any color swatches to your packet. Select some colors now by clicking a color above and then clicking the 'Request a Swatch' button on the color.

The products listed below are not exact equivalents. They are only products that you may consider as alternatives in a general sense. Substrate type, condition, temperatures, surface preparation, primer/topcoat selection and intended use are just a few factors that will affect product selection. Please contact your local Tnemec Coatings Consultant for product recommendations.

This ProductHDP Acrylic Polymer
Volume Solids Rec. DFT V.O.C. # of Components
40.0 ± 2.0% † 2.0 to 3.0 mils (50 to 75 microns) per coat. Unthinned: 0.79 lbs/gallon (94 grams/litre)
Thinned 5%: 0.79 lbs/gallon (94 grams/litre) †
One
Series 30 | Spra-Saf EN Hydrophobic Acrylic Polymer
Hide this product's data
Volume Solids Rec. DFT V.O.C. # of Components
38.0 ± 2.0% † 2.0 to 4.0 mils (50 to 100 microns) per coat. Note: Number of coats required will vary depending on color, substrate (surface) and other variables. Contact your Tnemec representative. Unthinned: 1.60 lbs/gallon (192 grams/litre)
Thinned 5%: 1.60 lbs/gallon (192 grams/litre) †
One
Series 1028 | Enduratone HDP Acrylic Polymer
Hide this product's data
Volume Solids Rec. DFT V.O.C. # of Components
40.0 ± 2.0% † 2.0 to 3.0 mils (50 to 75 microns) per coat. Unthinned: 0.79 lbs/gallon (94 grams/litre)
Thinned 5%: 0.79 lbs/gallon (94 grams/litre) †
One