find your coatings consultants
Find and contact a coatings consultant near you.

Series 233 | Power-Tread LE

Generic Type Modified Polyamine Epoxy
Common Usage A lower viscosity, high-solids, multi-purpose epoxy that can be used as a primer, broadcast, slurry/broadcast, mortar, grout coat, and topcoat. Especially useful when penetration is needed to sufficiently anchor epoxy flooring systems over lightly profiled concrete surfaces. Protects concrete surfaces from impact, abrasion and mild chemicals.
Colors Clear. Can be field-tinted (Series 820 Field Tint) in 16 StrataShield colors and certain custom colors. Contact your Tnemec representative for additional information. Note: Epoxies chalk and yellow with age, extended exposure to UV and artificial lighting. Lack of ventilation, incomplete mixing, miscatalyzation or the use of heaters that emit carbon dioxide during application and initial stages of curing may cause amine blush, possibly affecting adhesion of subsequent topcoats.
Finish Gloss
Surfacer/Filler/Patcher Series 206, 215. Note: A repair kit of 201, 208 or 233 with Part C fumed silica, is available for small patching/surfacing repairs. For more extensive repairs and additional information, contact your Tnemec representative or Tnemec Technical Services.
Primers Self-priming or Series 201, 208, 237, 238 or 241
Topcoats Series 206, 206SC, 233, 237, 238, 247, 248, 252SC, 280, 280FC, 281, 282, 284, 285, 286, 287, 290, 291, 294, 295, 296 or 297. Note: If Series 233, 247 (clear), 248 (clear), 285, 294, 295 or 296 is selected for the finish coat over a decorative broadcast system, an intermediate coat of Series 233 (clear), 237 (clear), 238 (clear) or 284 is required. If Series 247 (tinted), 248 (tinted), 290, 291 or 297 is selected for the finish coat over a broadcast system, a grout coat of Series 233 (tinted) 237 or 238 (tinted), 280, 280FC or 281 is required.
Volume Solids 100% (mixed)
Recommended DFT Primer: 3.0 to 12.0 mils (75 to 300 microns) per coat.
Broadcast: 1/16" to 1/8" (Double broadcast or slurry broadcast required to achieve 1/8"). Mortar: 3/16” to 1/4” thickness.
Grout coat: 8.0 to 16.0 mils (203 to 406 microns).
Intermediate or Topcoat: 8.0 to 16.0 mils (203 to 406 microns).
Curing Time
TemperatureTo Topcoat/BroadcastTo Place in Service
75°F (24°C)6 to 8 hours16 to 24 hours
Note: If more than 16 hours have elapsed between coats, the coated surface must be mechanically abraded before topcoating. Curing time varies with surface temperature, air movement, humidity and film thickness.
Volatile Organic Compounds 0.00 lbs/gallon (0.0 grams/litre)
Theoretical Coverage 1,604 sq ft/gal (39.4 m²/L at 25 microns). See APPLICATION for coverage rates.
Number of Components Two: Part A and Part B (3 Parts A to 1 Part B by volume)
1
Category
2
Chemical Name(required)
3
Concentration
4
What is this?

Note: Not Recommended (NR), Not Tested (NT), Please Call (PC)

 

Chemical Recommended Use - What is this?

The chemical resistance data listed on this website should only be used for general reference purposes. Substrates, temperatures, chemical combinations, and other variables can affect the performance of a coating in chemical exposure. Please contact your local to finalize the most appropriate system for your project.

Click the following button to download a PDF of the list of chemicals below.

1 Product is NOT suitable for direct or indirect food contact. Intended Use and temperature information relates    to product's performance capabilities only.

2 Product is suitable for direct or indirect food contact. Reference the product data sheet for more information.


Recommended Use
Chemical Occasional Contact Frequent Contact Secondary Containment Cargo Immersion Immersion Service

1 Product is NOT suitable for direct or indirect food contact. Intended Use and temperature information relates    to product's performance capabilities only.

2 Product is suitable for direct or indirect food contact. Reference the product data sheet for more information.

  • Color cards, swatches and fan decks are offered at no charge, by request , for more accurate color selection. Expert custom color matching is also available by contacting your Tnemec Coatings Consultant .
  • Deeptone colors may be more expensive than lighter colors. Please contact your Tnemec Coatings Consultant to verify product/color availability and pricing.

Products Available In White 11WH

White| 11WH (formerly WH01) rgb 242,238,231
Request a Swatch Swatch Unavailable
These digital colors should not be used to finalize your color selection. Please read our disclaimer . Use the color swatch tool on the left to request official color swatches.

Color Swatch Packet

Request another

(maximum 6 color swatches)

You haven't added any color swatches to your packet. Select some colors now by clicking a color above and then clicking the 'Request a Swatch' button on the color.

The products listed below are not exact equivalents. They are only products that you may consider as alternatives in a general sense. Substrate type, condition, temperatures, surface preparation, primer/topcoat selection and intended use are just a few factors that will affect product selection. Please contact your local Tnemec Coatings Consultant for product recommendations.

This ProductModified Polyamine Epoxy

French version of product datasheet is currently not available.

GET THE LATEST NEWS AND UPDATES BY EMAIL FROM TNEMEC

support documents